Back to top
Send Inquiry
CED Coating Machine

CED Coating Machine

Product Details:

X

Product Description

CED Coating Machine

Holding years of experience and knowledge in this industry, our company has been able to mark its strong presence in the market as one of the most excellent service providers of CED Coating Machine. All the services are rendered to the clients as per their requirements and that too within the given time frame. Offered to the client’s at best affordable price, our CED Coating Machine services are rendered by the team of highly skilled personnel with the help of latest tools and technology.

Further Details

CED Coating Machine

We deal in CED coating machine. 

Stage 1 of CED : HOT WATER: Operating temperature of 55°-65°. This stage removes light surface oxides .

Stage 2 of CED : K.O.D: Alkaline Cleaner. Operating temperature of 55°-65°. This stage applies cleaner with oscillating spray nozzles to remove light surface oxides as well as any remaining lubricants. 

Stage 3 of CED : DEGREASING:  Alkaline Cleaner. Operating temperature of 55°-65°. This stage applies cleaner with oscillating spraynozzles to remove light surface oxides as well as any remaining lubricants. 

Stage 4 of CED : R.O.WATER RINSE: Ambient operating temperature. This stage removes soils loosened by cleaner as well as removing cleaner residue. 

Stage 5 of CED : R.O.WATER RINSE: Ambient operating temperature. This stage removes soils loosened by cleaner as well as removing cleaner residue. 

Stage 6 of CED : SURFACE CONDITIONER:  Ambient operating temperature. This stage prepares the cast/metal surface to accept the ZincPhosphate coating. 

Stage 7 of CED : ZINC PHOSPHATE : Operating temperature of 40° - 45°. This stage applies a Trimetal Zinc Phosphate coating as a corrosion protective base for the paint coating. 

Stage 8 of CED : DI WATER RINSE: Ambient operating temperature. This stage removes the Zinc Phosphate salts and stops Zinc Phosphate reaction. 

Stage 9 of CED : DI WATER RINSE: Ambient operating temperature. This stage removes the Zinc Phosphate salts and stops Zinc Phosphate reaction 

Stage 10 of CED : DI WATER RINSE: D.I. Water. Ambient operating temperature. This stage is a purifying rinse to remove excess phosphate and sealer. It lowers the surface conductivity of the part to prepare it for ecoating.

 Stage 11 of CED : ELECTROCOAT BATH: Operating temperature of 28°(plus or minus 2°). This stage applies positive charged paint to a negativecharged part. This gives the part an electro deposition paint coating. 

Stage 12 of CED : UF-1 (Ultra Filter): D.I. Water. Ambient operating temperature. This stage removes excess e-coat from the parts. It counterflows paint solids back to the e-coat tank to enable a high efficient operation 

Stage 13 of CED : UF-2 (Ultra Filter 2): D.I. Water. Ambient operating temperature. This stage applies a permeate spray to assist in the removal ofexcess ecoat. It counter flows paint solids back to the e-coat tank to enable a high efficient operation. 

Stage 14 of CED : DI WATER RINSE: D.I. Water. Ambient operating temperature. This stage removes excess e-coat from the parts. It counterflows paint. It Lowers the Surface conductivity of the par. 

Stage 15 of CED : BANKING OVEN: Time :10 min, EMT: 160 Degree



Corporate Office:

834/1, Block-k, Mahipalpur, New Delhi - 110037, India
Phone:91-11-26788114
Fax:91-11-26781200